Veris-technologies Quad 1000 Soil EC Mapping System - Operating Instr Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Veris-technologies Quad 1000 Soil EC Mapping System - Operating Instr. Veris Technologies Quad 1000 Soil EC Mapping System - Operating Instructions User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 43
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
OM17-Quad1000
1-1
Quad 1000
Soil EC Mapping System
Table of Contents
Section 1
1-2 Warranty
1-3 Safety
Section 2
2-1 Electronics Overview and Set-up: EC Surveyor
2-3 Electronics Overview and Set-up: DataLogger
2-4 Software Set-up: SoilViewer
Section 3
3-1 Implement Overview and Set-up
3-2 Additional Assembly Instructions
Section 4
4-1 Field OperationsEC Surveyor
4-2 Field OperationsEC Surveyor with DataLogger
4-4 Field OperationsEC Surveyor with SoilViewer software
4-5 Field Operations--Implement
Section 5
5-1 Troubleshooting
5-2 SoilViewer Troubleshooting
Section 6 Maintenance and Service Procedures
6-1 #1. EC Surveyor signal testing
6-2 #2. Testing electrical continuity
6-4 #3. Diagnosing and correcting EC signal problems
6-10 #4. Spring plunger testing and replacement
6-12 #5. Diagnosing GPS-related problems
6-16 #6. Firmware updates and SD card formatting
6-19 #7. Implement lubrication
6-19 #8. Maintenance
6-20 #9. Micro-chip replacement
Operating Instructions
Przeglądanie stron 0
1 2 3 4 5 6 ... 42 43

Podsumowanie treści

Strona 1 - Soil EC Mapping System

OM17-Quad1000 1-1 Quad 1000 Soil EC Mapping System Table of Contents Section 1 1-2 Warranty 1-3 Safety Section 2 2-1 Electronic

Strona 2 - Section 1

OM17-Quad1000 3-1 Section 3 Implement Overview and Set-up Figure 1. The tongue must be installed prior to use. To do so, please

Strona 3 - Section 2

OM17-Quad1000 3-2 NOTE: Depending on shipping configuration, the unit may need additional assembly. Attach wheels as shown in Figure 3. Attach raise-l

Strona 4

OM17-Quad1000 3-3 Install weight bracket if included as shown in Figure 7. A choice of assembly positions is available to accommodate customer-provid

Strona 5

OM17-Quad1000 4-1 Section 4 Field Operations—Soil EC Surveyor Attach the signal cable to the quick connect coupler at front of frame, and to Signal p

Strona 6

OM17-Quad1000 4-2 Field Operations—Soil EC Surveyor with Sensor DataLogger Before logging any data, make sure the SD card in the Datalogger is clear

Strona 7

OM17-Quad1000 4-3 If memory card was not inserted during boot-up, the following screen will appear: Figure 8 Install card and re-start DataLogger.

Strona 8

OM17-Quad1000 4-4 Field Operations—Soil EC Surveyor with SoilViewer software The EC Mapping software will automatically detect which port the Veris E

Strona 9

OM17-Quad1000 4-5 Field Operations--Implement Checking Electrical Signal Continuity and Electrode Isolation It is recommended that you perform the E

Strona 10 - Section 3

OM17-Quad1000 4-6 Swath width and Navigation Setting the swath width and navigation system is at the discretion of the customer. A 50’-75’ (15-23 m)

Strona 11

OM17-Quad1000 5-1 Section 5 Troubleshooting EC data seem odd—jumpy, negatives, map doesn’t match known or expected soil types Perform Maintenance an

Strona 12 - Install weight bracket

OM17-Quad1000 1-2 Quad 1000 Soil EC Mapping System Soil EC Surveyor Software Version 1.2 Sensor DataLogger Version 1.03 Section 1 Warranty Veris Tec

Strona 13

OM17-Quad1000 5-2 SoilViewer Troubleshooting EC Surveyor is not found Check to ensure the com which the EC Surveyor is connected to is present under

Strona 14

OM17-Quad1000 5-3 Reinstalling USB- Serial Converter (Part# 41377) Drivers Insert the Veris SoilViewer disk once the Veris SoilViewer appears click c

Strona 15

OM17-Quad1000 6-1 Section 6 Maintenance and Service Procedure #1: EC Surveyor Instrument Signal Testing Perform this test daily or every 10 ho

Strona 16

OM17-Quad1000 6-2 Procedure #2: Testing Electrical Continuity Perform this test daily or every 10 hours of data collection to ensure you are obtaini

Strona 17

OM17-Quad1000 6-3 Figure 2.2 Firmly press one lead of the ohmmeter to the #1 disk blade edge (left hand, standing behind the unit) and the other l

Strona 18

OM17-Quad1000 6-4 Figure 3.1 Procedure #3: Diagnosing and Correcting EC Signal Problems. Use this Troubleshooting tree to work through the system,

Strona 19

OM17-Quad1000 6-5 Disk Electrode Functions- Each disk electrode on the implement is part of a pair, and each pair has a distinct function. a) Disks

Strona 20

OM17-Quad1000 6-6 Coulter 2Coulter 4Coulter 3Coulter 1 Figure 3.3. Check continuity of signal harness, with o

Strona 21

OM17-Quad1000 6-7 Figure 3.5 2. If ohms jump over 2 ohms when the blade is rotated, and you were careful to maintain good contact between the lead

Strona 22 - Section 6

OM17-Quad1000 6-8 C. Testing Disk-Electrode isolation If continuity tests show no excessive resistance on any channel, yet erratic soil EC readings

Strona 23

OM17-Quad1000 1-3 Important! Read the following SAFETY PROCEDURES before operating the Veris system: • Read and understand all instructions on saf

Strona 24

OM17-Quad1000 6-9 Figures 3.10 a and b 4. Wet soil on the toolbar could be a pathway for the EC signal to short. Test disk-to-disk and disk

Strona 25

OM17-Quad1000 6-10 Procedure #4 Spring Plunger adjustment and replacement The spring plungers are located in the center of each disk electrode hub ca

Strona 26

OM17-Quad1000 6-11 Procedure: 1) Remove hub cap by removing the four carriage bolts. 2) If plunger is frozen in cap, remove the 3/8” nut on the o

Strona 27 - Coulter 4

OM17-Quad1000 6-12 Procedure #5: Diagnosing GPS-related problems If you do not see a GPS, DGPS, or RTK in the upper left-hand corner of the EC Survey

Strona 28

OM17-Quad1000 6-13 If it becomes necessary to send GPS data into your PC, you will use a program called HyperTerminal. This program is in all Windows

Strona 29

OM17-Quad1000 6-14 5. The program will then ask you for a phone number. Instead of entering a phone number, specify the proper serial port number.

Strona 30

OM17-Quad1000 6-15 7. At this point, upon clicking ok, legible strings of GPS data should begin appearing on the laptop screen. Here’s an example of

Strona 31

OM17-Quad1000 6-16 Procedure #6: SD card formatting and firmware updates USING A VERIS SD CARD IN OTHER DEVICES CAN CAUSE FILE CORRUPTION. Insert

Strona 32

OM17-Quad1000 6-17 Figure 6.2. 6. Hold the (1) key and release the RESET button. 7. If you can see the following messages, then release the (1) key

Strona 33

OM17-Quad1000 6-18 9. Then you can see the following messages in sequence. Figures 6.4 a and b. 10. Do not shut off the power, but repeat from ste

Strona 34

OM17-Quad1000 2-2 Figure 1. EC Surveyor kit Figure 2. DataLogger kit

Strona 35

OM17-Quad1000 6-19 Procedures #7: Lubrication and #8: Maintenance Raise/lower crank: this should be lubricated on 20-hour intervals. This may vary

Strona 36

OM17-Quad1000 6-20 Procedure #9: Removing EC Surveyor Cover: Microchip Replacement and Q1000 to 3150 Resistor Change It may be necessary to open th

Strona 37

OM17-Quad1000 6-21 Replacing microchip. If microchip fails, or if unit needs updated firmware, it will be necessary to remove chip and replace with ne

Strona 38

OM17-Quad1000 6-22 Figures 9.5 a, b, c 9a: Resistor installed for Q1000, 2000XA and 3100 models; 9b and c: position for

Strona 39

OM17-Quad1000 2-3 Figure 4. EC Surveyor (rear) Figure 5. EC Surveyor (front) Figure 6. DataLogger (rear) Power port: The S

Strona 40

OM17-Quad1000 2-4 Figure 7. DataLogger (front) Important – Do not allow moisture to enter the Soil EC Surveyor or Sensor Da

Strona 41

OM17-Quad1000 2-5 Software Setup Figure 8. Figure 9. Figures 10a and 10b. The Veris SoilViewer software will automatically run the setup o

Strona 42

OM17-Quad1000 2-6 Figure 11. Figure 12 The installer will install all necessary components Once the installer is completed, click finish

Strona 43

OM17-Quad1000 2-7 Figure 13 Figure 14 Figure 15 Figure 16 The Veris SoilViewer will now install drivers necessary to operate the included U

Komentarze do niniejszej Instrukcji

Brak uwag

Watson-Marlow SPS manuales

Manuales del propietario y guías del usuario para Zapatillas Watson-Marlow SPS.
Ofrecemos 2 manuales en pdf Watson-Marlow SPS para descargar gratis por tipos de documentos: Manual de usuario


Watson marlow SPS Manual de usuario (142 paginas)


Marca: Watson-marlow | Categoria: Pumps | Tamaño: 5.93 MB |

 

Tabla de contenidos

MasoSine Process Pumps

1

SPS sinusoidal pumps

1

Contents

1

1 Declaration of conformity

2

3 Warranty and liability

3

4 When you unpack your pump

4

7 Safety notes

6

7.4 Personnel training

7

7.5 Safety measures

7

7.8 Protective devices

8

7.14 Noise

9

7.12 Special danger points

9

7.16 Maintenance and repair

10

Bearings maintenance

11

7.17 Cleaning the pump

12

7.18 Faults

12

8 Safety notes (ATEX)

13

8.2 Earthing the pump

14

8.3 Material properties

14

8.4 Pressure conditions

14

8.5 Maintenance and repair

14

9 Pump specifications

15

Standards

16

SPS 200 pumps, dimensions

17

Cast iron power frame

17

Stainless steel power frame

17

SPS 250 pumps, dimensions

18

SPS 300 pumps, dimensions

19

SPS 400 pumps, dimensions

20

Unit weights

21

SPS 500 pumps, dimensions

21

10 Transport

22

11 Installation

22

12 Connection to the piping

23

12.1 Cavitation

24

13 Possible pump orientations

25

15 Start-up and operation

27

14 Connecting this product

27

16 Flushing the seal system

28

17 Cleaning and sterilisation

29

3 bar / 43.5 psi

30

18 Heating and cooling option

31

19 Oil change

32

20 Troubleshooting

33

Adjusting the shaft

35

SPS 200

36

SPS 300

36

SPS 400 pumps

36

22 Dismantling and assembly

39

Removing the locking nut

40

SPS 100 pumps

40

Removing the sealing system

45

Disassembling the seals

46

22.2.2 Assembling the SPS 100

47

mechanical seal

48

Fitting the front cover

52

Fitting the locking nut

52

Removing the front cover

53

SPS 200 pumps

53

Removing the front liner

55

Removing the shaft nut

56

22.3.2 Assembling the SPS 200

66

Fitting the shaft nut

76

Fitting the front liner

77

Fitting the front support

77

SPS 250, SPS

79

300, SPS 400

79

The backing ring

83

The dynamic ring holder

84

SPS 400 and SPS 500

88

23 The static flushing device

96

SPS 300 and

98

24 Tightening torques

102

” DIN 908

103

25 Parts lists

104

25.1 Pumps

105

Integral with

108

Type depends on

108

SPS 400 with cast iron frame

117

25.2 Seals

123

Cup with dynamic surface

127

SiC – FPM/FKM

127

25.3 Front support versions

133

With cast iron power frame

139

27 Trademarks

142

28 Publication history

142





Más productos y manuales para Zapatillas Watson-Marlow

Modelos Tipo de documento
620U Manual de usuario   Watson-Marlow 620U User Manual, 100 paginas
620R Manual de usuario   Watson-Marlow 620R User Manual, 19 paginas
701 Manual de usuario   Watson-Marlow 701 User Manual, 25 paginas
700 series Manual de usuario   Watson-Marlow 700 series User Manual, 11 paginas
PD/40 Manual de usuario   Watson-Marlow PD/40 User Manual, 24 paginas
Qdos30 Universal Manual de usuario   Watson-Marlow Qdos30 Universal User Manual, 78 paginas
DuCoNite 25 Manual de usuario   Watson-Marlow DuCoNite 25 Manuel d'utilisation, 76 paginas
120S/DV Manual de usuario   Watson-Marlow 120S/DV Manuel d'utilisation, 29 paginas
520Du Manual de usuario   Watson-Marlow 520Du Manuel d'utilisation, 107 paginas
501RL ATEX Manual de usuario   Watson-Marlow 501RL ATEX Manuel d'utilisation, 10 paginas
520DiN Manual de usuario   Watson-Marlow 520DiN Manuel d'utilisation, 151 paginas
120F/DV Manual de usuario   Watson-Marlow 120F/DV Manuel d'utilisation, 25 paginas
505L Manual de usuario   Watson-Marlow 505L Manuel d'utilisation, 17 paginas
Bredel 265 Manual de usuario   Watson-Marlow Bredel 265 Manuel d'utilisation, 96 paginas
Qdos30 Remote Manual de usuario   Watson-Marlow Qdos30 Remote Manuel d'utilisation, 40 paginas
Qdos60 Universal+ Manual de usuario   Watson-Marlow Qdos60 Universal+ Manuel d'utilisation, 77 paginas
101F Manual de usuario   Watson-Marlow 101F Manuel d'utilisation, 14 paginas
205S Manual de usuario   Watson-Marlow 205S Manuel d'utilisation, 12 paginas
620UN/620U Manual de usuario   Watson-Marlow 620UN/620U Manuel d'utilisation, 94 paginas
DuCoNite 25 Manual de usuario   Watson-Marlow DuCoNite 25 Benutzerhandbuch, 80 paginas